Solutions
MSC & EV scale-up manufacturing solutions
Take MSC cell therapies and MSC-derived extracellular vesicles (EVs) from the lab to clinical batches: select seed cells and ancillaries, 2D-to-3D scale-up, media and feeds, EV collection and downstream purification, characterisation, and fill-finish as one connected chain, and avoid rework at scale-up.
Definition
A workflow-based selection guide for process development and scale-up manufacturing of MSC cell therapies and MSC-derived EVs/exosomes, covering the key materials and equipment for cell banks, serum-free culture, Vertical-Wheel bioreactor scale-up, TFF and SEC purification, single-particle characterisation, and closed filling and cryopreservation.
Scale-up is not just a bigger vessel
MSC and MSC-EV programmes rarely stall because one step cannot be done; they stall because every step chose its own materials. Serum-containing media and multilayer flasks work in research, then at pilot scale background particles drown the EV signal, cumulative downstream recovery falls to single digits and key materials have no master file to reference. This solution splits MSC/EV manufacturing into six stages, with selection points and published data for each, so that the process is built from the first batch on a route that scales and connects to regulatory preparation.
1. Seed cells and cGMP ancillaries: fix the starting point
- Tiered cell banks: RoosterBio's cell banks come as QuickShip research grade, DEV+ preclinical development grade (same donor as the clinical bank, 1E7 cells per vial) and cGMP CliniControl clinical grade (2E7 cells per vial, supported by an FDA Type II Master File), so development and clinical work can stay on one donor.
- Track cell age by PDL, not passage number: in a worked example published by Solallis, seeding at 78 cells/cm² and growing to 20,000 cells/cm² takes about 8 doublings per passage, so cells at P2 have accumulated 16 doublings, equivalent to P8 in a 5,000 cells/cm² seeding process; guidance such as ICH Q5D calls for accurate estimation at every stage of research, development and manufacturing.
- Serum and its alternatives: GeminiBio submitted a DMF for its cGMP-grade human serum to the FDA in 2025; Akron human AB serum is manufactured, tested and released under the relevant cGMP ancillary-material requirements, with sterility, mycoplasma and endotoxin testing; Sexton human platelet lysate (hPL) comes as Stemulate CP, nLiven PR and T-Liven PR, with multi-lot testing of pH, osmolality and total protein giving a lot-to-lot CV below 10%.
- Starting from tissue: Nordmark offers collagenase tissue-dissociation solutions from research to GMP grade; the GMP allogeneic adipose MSC process at Rigshospitalet, Denmark, digests adipose tissue with GMP-grade collagenase NB6.
2. 2D to 3D scale-up: PBS Biotech Vertical-Wheel bioreactors
- Low-shear environment: according to the manufacturer, the Vertical-Wheel design delivers shear stress of 0.05–0.2 Pa for microcarrier and 3D-aggregate culture of shear-sensitive cells such as MSCs and iPSCs.
- One vessel family: PBS-Mini 0.1 L and 0.5 L for early process development, then PBS-3 (3 L) and PBS-15 (15 L) up to PBS-80 (80 L) at commercial scale.
- Potency survives scale-up: Massoumi et al. (Small, 2026) found in a mouse corneal-injury model that corneal MSC-EVs from vertical-wheel 3D culture raised corneal nerve length to 51.9 mm on day 14, versus 23.3 mm for the collection-medium control and 32.3 mm for 2D EVs from the same source (3D vs 2D, P = 0.04); another study cultured human forebrain organoids on microcarriers in the PBS Mini and raised EV yield 240–750-fold over static aggregates.
- Set parameters small, then scale: in data presented by RoosterBio and Sartorius Stedim North America at ISEV 2023, critical process parameters were set at 250 mL (Synthemax II microcarriers, 3X microcarrier density, 1X seeding density, 5-day growth plus 5-day collection) before scale-up to a 15 L Biostat STR, where cell density reached about 4E5 cells/mL on growth day 5, particle concentration about 1.7E10 particles/mL on collection day 5, and about 91% of particles were membrane-dye positive.
3. Media and feeds: design expansion and collection separately
- The RoosterBio suite: RoosterNourish-MSC-XF needs no medium change or surface coating and gives over 10-fold expansion in 4–5 days when seeded at 3,000 cells/cm²; cGMP-grade prcRoosterNourish-MSC-CC (K82304) uses pathogen-reduced components, is supported by an FDA Type II Master File and gives an average doubling time of about 29.3 hours; in 3D bioreactors, RoosterReplenish feed removes half or full medium exchanges.
- All-in-one expansion and collection: Rooster HD-EV is fully chemically defined; according to the manufacturer, EV yield is 10–20-fold that of conventional batch culture, background particles are ≤1.0E8 particles/mL and production can run continuously for up to 12 days in a 3D bioreactor.
- The chemically defined route: Solallis Stem Design MSC Culture Medium AF (M101-AF-500) is ready to use and EV-free; manufacturer data show serum-free passaging of adipose MSCs to P14, a doubling time of about 20 hours and a culture cycle cut from 9 to 6 days; with the M201-AF-500 EV collection medium it forms an animal-origin-free system.
- Selection point: XF, AF and CD are three different formulation logics, not one ladder. CD has the smallest lot-to-lot variation with fully traceable components; XF adapts easily and behaves closest to serum systems. When switching media, compare lot consistency, downstream purification burden and regulatory needs item by item.
4. EV collection and downstream purification: recovery sets the cost per dose
- A clean collection matrix: RoosterCollect-EV has a release specification of ≤1E8 particles/mL and a 6–72 hour collection window; cGMP-grade RoosterCollect-EV-CC (M02004) comes in large-volume bags, carries from 2D culture to 200 L-class 3D stirred-tank bioreactors and is supported by an FDA Type II Master File.
- Fix filter fouling: conventional processes recover only 5%–10% of particles cumulatively downstream. RoosterBio Agent V-DSP (S46999) is added at 1 mL per litre of medium and incubated for 30 minutes at room temperature before downstream processing; in the complete RoosterBio system scenario cumulative recovery reached 40%–70% and the number of 50 L bioreactors needed for 2,500 doses fell from 8 to 1, with EV size distribution and CD63/CD9/CD81 markers unchanged by treatment.
- Concentrate and buffer-exchange before SEC: in an official IZON poster, conditioned medium was concentrated and buffer-exchanged with qEV TFF, cleared of protein with qEV220 SEC and collected automatically with qEV Zenco, giving about 15-fold purity improvement, about 96% protein removal and highly consistent elution profiles over 20 consecutive runs.
- Choosing columns: qEV columns run from qEVsingle (≤150 μL) to qEV100 (≤100 mL) with 20, 35 and 70 nm pore sizes; 35 nm Gen 2 columns deliver on average 4.6 times the EV particles per μg total protein of legacy columns; GMP-Ready versions with CoA support translational stages, and the AFC automatic fraction collector or qEV Zenco reduces manual error.
5. Characterisation: at least two complementary methods
- MISEV2023 recommends that physical EV characterisation use at least two complementary techniques for orthogonal validation.
- IZON Exoid uses tunable resistive pulse sensing (TRPS) to measure size, concentration and zeta potential particle by particle; with a quadrimodal standard it baseline-resolved all four particle populations, while NTA missed one and MADLS could not resolve them. The sample is recovered after measurement for cross-validation by NTA, nano-flow cytometry or TEM.
6. Filling and cryopreservation: turn a batch into releasable doses
- Closed filling: according to Sexton, the CT-5 cell filling system has a dual low-speed and high-speed pump design, fills cryovials and cryobags, achieves fully closed filling in a Grade C laboratory and fills at up to 525 mL/min.
- Primary packaging: CellSeal cryovials are made of USP Class VI medical plastic that resists low temperature, DMSO and breakage; according to Sexton they have been part of the approved projects of more than 40 IND drugs in more than ten countries and 2 marketed drugs.
- Freezing medium: Akron CryoNovo P24 is DMSO-free, serum-free and free of animal-derived components, ready to use without dilution and wash-free after thawing, with post-thaw cell viability ≥70%.
- Long-term stability reference: in a GMP allogeneic adipose MSC study at Rigshospitalet, Denmark, cells expanded in two stages in a closed bioreactor with 5% heparin-free hPL; all 36 batches met release criteria and viability after 24 months at −180 °C was 91–94%.
Let TechWave connect the six stages into one chain
Whether you are developing an MSC process, scaling MSC-EVs to pilot scale or preparing IND material documentation, contact TechWave. We can compile specifications, documentation and application data for RoosterBio, Solallis, PBS Biotech, IZON, Sexton, Akron, GeminiBio, Nordmark and other brands by cell source, target scale and project stage, plan a material path from research grade to GMP grade, and arrange a quotation. For MSC research tools or the complete exosome separation and characterisation line-up, see the MSC research solutions and exosome solutions under related solutions below.
Uses and applicable scenarios
- MSC cell-therapy process development and 2D-to-3D scale-up
- MSC-EV/exosome scale-up production, downstream purification and characterisation
- Switching from research-grade to cGMP-grade materials and preparing IND material documentation
Limitations
- Data on this page come from manufacturer information or published studies under specific conditions (cell source, vessel size, process parameters); results in your own process depend on validation under the target conditions.
- The manufacturer labels Akron CryoNovo P24 for research and further manufacturing use only and does not recommend direct human clinical use.
Related brands
Related products
- CryoNovo P24
- AR1010-0100 / AR1048-100/60
- GeminiBio Human Serum AB
- Access Biologicals/Grifols Human Male AB Serum
- IZON Automatic Fraction Collector (AFC)
- N0002779
- N0002880
- N0002937
- N0002936
- N0003855
- N0003554
- N0003553
- N0003716
- N0002778
- S1745503
- S1745401
- Collagenase NB Products
- PBS Vertical-Wheel Bioreactors
- PBS-Mini 0.1L
- PBS-Mini 0.5L
- PBS-Mini 0.1L and 0.5L
- K87036/K87312/K87206/K87027
- K82304
- S46999
- M02004
- C43001UC / C43002UC / C56010UC / C04020UC
- MSC-031 / MSC-030 / C44010BM / MSC-CC040
- C46001AD / C46010AD
- C55001DF / C53010DF / C06020DF
- K82016
- SU-023
- M2001
- PL-CP-NH-100/500 (research grade)/PL-CP-SP-100/500 (GMP grade)
- TL-PR-150C
- PL-PR-100/500
- M101-AF-500
- M201-AF-500
Technical resources
- Your P2 MSCs May Already Match Someone Else's P8: Stop Relying on Passage Number and Define MSC True Age by Population Doubling Level (PDL)
- One-stop iPSC workflow selection: from reprogramming, expansion, gene editing and directed differentiation to 0.1–80 L suspension scale-up, 525 mL/min closed filling and ambient transport for up to 2 weeks
- Most of the Exosomes You Worked Hard to Grow Are Lost in Downstream Filtration: RoosterBio Agent V-DSP Relieves Filter Fouling and Lifts Cumulative Downstream Particle Recovery from 5%–10% to 40%–70%
- Low exosome yield and too many medium changes? Rooster HD-EV all-in-one expansion and collection medium: 10–20-fold more EVs than conventional batch culture, background ≤1.0E8 particles/mL
- Solallis M101-AF chemically defined MSC medium: serum-free passaging to P14, over 100,000-fold primary expansion in two weeks, doubling time of about 20 hours
- Scaling MSC-EV from 250 mL to 15 L without losing yield or quality: about 4E5 cells/mL, about 1.7E10 particles/mL and about 91% membrane-dye-positive particles
- Replacing FBS with hPL: lot-to-lot CV below 10%, no marked loss of growth factors after E-beam treatment, and higher expansion than FBS
- Why choose Exoid: TRPS baseline-resolved all four populations of a quadrimodal standard and measures size and zeta potential particle by particle from 35 µL
- Is pilot-scale CCM exosome purification stuck on viscosity and protein? qEV TFF + qEV220 SEC: about 15-fold purity gain, about 96% protein removal, consistent elution over 20 consecutive runs
- One exosome sample, three sizes from DLS, NTA and TRPS — which do you trust? The five EV characterization techniques explained, and iZON Exoid measuring size, concentration and single-particle zeta potential in one run
- MSC-EV yields too low and background particles drowning the signal? RoosterBio's four-stage media suite: over 10-fold expansion in 4–5 days and collection medium at ≤1E8 particles/mL
- Choosing an Exosome SEC Column Without Pitfalls: A Complete iZON qEV Selection Guide, 6 Column Sizes from 150 μL to 100 mL, 20/35/70 nm Pore Sizes, and 35 nm Gen 2 Averaging 4.6 Times the EV Particles per μg Protein of Legacy Columns
- Choosing XF, AF or CD serum-free media: adaptation, lot consistency, downstream purification and compliance — 7 dimensions in one table
- From a tube of fat to a GMP “off-the-shelf” cell therapy: all 36 batches released and 91–94% viability after 24 months at −180 °C — the allogeneic adipose MSC chain built on 5% heparin-free hPL and closed reactors
- Vertical-wheel 3D corneal MSC-EVs more than double mouse corneal nerve length versus control: 51.9 mm vs 23.3 mm
- Does Scale-Up Have to Hurt Your Cells? PBS Biotech's Vertical-Wheel Bioreactor Wins a 2026 Cell Therapy Product Development Award and Joins Organoid COMMONS: Low Shear and Linear Scale-Up for Industrializing Organoids and Cell Therapy
- Human AB Serum Sits Upstream, Yet It Can Still Stall a CGT IND or BLA: What a DMF Does, What It Cannot Do for You, and GeminiBio's Path from Research-Grade to Clinical-Grade Serum and Documentation
- The Cell Bank Is the Entry Ticket for MSC and EV Drug INDs: RoosterBio's Three Tiers from Research Grade to cGMP CliniControl, Checked Item by Item Against CDE Testing Requirements
- Scale Is the Engineering Goal, Equivalence Is the Hard Constraint: RoosterBio Anchors MSC 2D-to-3D Comparability on Cell Age (PDL), with Multi-Donor Final PDL of 16–20 and More Than 25 Billion Cells per 50 L Batch
