Solutions

Exosome solutions

Upstream cell culture, supernatant collection, exosome separation, purification, concentration and particle characterisation.

Definition

Upstream cell culture, supernatant collection, exosome separation, purification, concentration and particle characterisation.

Solution overview

Upstream cell culture, supernatant collection, exosome separation, purification, concentration and particle characterisation.

Explore the workflow

Use the linked brands, products and technical resources to move from the research need to product-level information.

Uses and applicable scenarios

  • Upstream cell culture
  • Separation, purification and concentration
  • Particle sizing and characterisation

Limitations

  • Confirm product specifications and applicability against the current manufacturer documentation.

Research guide

The extracellular vesicle workflow: production, purification and characterization

How do you link EV upstream culture, downstream purification and characterization into one scalable workflow whose data stands up to scrutiny?

The short answer: EV yield and quality are set jointly by three stages, and optimizing any one alone is not enough. Upstream, cell expansion and EV collection should be designed separately, collection should use a low-background-particle medium, and multiple critical quality attributes should show the particles have not changed after scale-up. Downstream is where most EVs are lost, with cumulative particle recovery of only 5%–10% in conventional processes; TFF concentration followed by SEC protein removal is a common scalable route. Characterization should follow MISEV2023 with orthogonal verification by at least two techniques based on complementary principles, because the same sample naturally gives different sizes on DLS, NTA and TRPS.

Upstream: expand first, then collect, and match quality after scale-up

RoosterBio splits MSC-EV production into expansion, clean collection, 3D scale-up and clinical translation: RoosterNourish-MSC-XF expands cells more than 10-fold in 4–5 days, and RoosterCollect-EV is released at ≤1E8 particles/mL; according to manufacturer data, the integrated Rooster HD-EV raises EV output 10–20-fold over conventional batch culture. For scale-up evidence, in a RoosterBio and Sartorius poster a 15 L Biostat STR reached about 1.7E10 particles/mL on collection day 5, with about 91% of particles membrane-stain positive and a size distribution matching 250 mL. 3D Vertical-Wheel culture also changes the EVs themselves: in a mouse corneal model, nerve length reached 51.9 mm with 3D-derived corneal MSC-EVs versus 23.3 mm for the collection-medium control.

  • MSC-EV yields too low and background particles drowning the signal? RoosterBio's four-stage media suite: over 10-fold expansion in 4–5 days and collection medium at ≤1E8 particles/mL

    Scaling MSC-EV production has long been blocked by three problems: low yield, unstable quality and processes that will not scale. RoosterBio splits production into expansion, clean collection, 3D scale-up and clinical translation, each with a dedicated medium: RoosterNourish-MSC-XF needs no medium change or surface coating and gives over 10-fold expansion in 4–5 days; RoosterCollect-EV is chemically defined with a release specification of ≤1E8 particles/mL and a 6–72 hour collection window; 3D is validated beyond 50 L; and the cGMP line is supported by an FDA Type II Master File.

  • Low exosome yield and too many medium changes? Rooster HD-EV all-in-one expansion and collection medium: 10–20-fold more EVs than conventional batch culture, background ≤1.0E8 particles/mL

    Scaling exosome production is usually held back by low yield, high background impurities, laborious handling and high scale-up cost. Rooster HD-EV is a fully chemically defined medium that combines expansion and collection: cells grow while EVs are collected, and according to the manufacturer EV yield rises 10–20-fold over conventional batch culture. The medium's baseline particle background is ≤1.0E8 particles/mL, it needs no washing or medium change and runs fed-batch, and it supports continuous production for up to 12 days in a 3D bioreactor.

  • Scaling MSC-EV from 250 mL to 15 L without losing yield or quality: about 4E5 cells/mL, about 1.7E10 particles/mL and about 91% membrane-dye-positive particles

    The real question in upstream EV scale-up is not how much bigger the reactor gets, but whether particle yield and critical quality attributes still match once it does. A poster presented by RoosterBio and Sartorius Stedim North America at ISEV 2023 answers it: at 250 mL the critical process parameters were set (Synthemax II microcarriers, 3X microcarrier density, 1X seeding density, 5-day growth plus 5-day collection), giving 1–1.5E10 particles/mL at harvest with good donor-to-donor and N=3 vessel-to-vessel reproducibility; after scale-up to a 15 L Biostat STR, cell density reached about 4E5 cells/mL on growth day 5 and particle concentration about 1.7E10 particles/mL on collection day 5, about 91% of particles were membrane-dye positive, size distributions matched, CD63/CD9/CD81 and TSG101 were detected, and in a HUVEC scratch assay activity exceeded unconditioned medium and matched growth medium.

  • Vertical-wheel 3D corneal MSC-EVs more than double mouse corneal nerve length versus control: 51.9 mm vs 23.3 mm

    Corneal MSC-EVs from a vertical-wheel 3D process reached 12.64 mm neurite length (5.3 mm for 2D) and more than doubled mouse corneal nerve length versus collection-medium control (51.9 vs 23.3 mm), about 1.6-fold the 2D-derived EVs (32.3 mm, P = 0.04). 3D culture reshaped EV miRNA cargo, mainly in bone-marrow MSC-EVs; corneal EV cargo stayed relatively stable.

  • MSC extracellular vesicles from 3D culture are not just more numerous: more varied in composition and stronger at promoting neurite growth in vitro

    Moving mesenchymal stromal cells (MSCs) from flasks into a bioreactor brings one obvious change: many more vesicle particles in the harvest. But are the extra vesicles the same kind as before? A 2022 study in Stem Cell Research & Therapy compared 2D and 3D culture of bone-marrow MSCs from 3 donors. EV concentration in 3D was 24 to 28 times that in 2D, though the difference did not reach statistical significance, which the authors attribute probably to the small number of repeats. More notably, 3D-derived EVs had a visibly more varied surface-marker make-up and promoted neurite growth more strongly in mouse trigeminal ganglion neurons (average neurite length 3301.5 μm versus 1860.5 μm). This article takes apart those three layers of change and the questions the study leaves open.

  • Why the Exosome Collection Step Needs a Medium of Defined Composition: Evidence on Medium-Derived Particles, and Four Ways to Verify

    In MSC exosome work, expanding cells in medium containing serum or human platelet lysate (hPL) is common. At the step where conditioned medium is collected, however, these supplements carry their own vesicles and particles into the product. A 2014 study isolated exosomes from hPL, and another found that vesicles in fetal bovine serum are not removed by 1.5 hours of ultracentrifugation. The International Society for Extracellular Vesicles' MISEV2023 guidelines also state that serum and platelet lysate are rich in vesicles and particles, and that commercial “EV-free” products should not be assumed to be vesicle-free without verification. China's Clinical Research Filing Guideline for Cell Component and Derivative Therapy Technologies (1st edition, April 2026) splits manufacturing into two steps accordingly: the expansion step may use serum or a serum substitute prepared under GMP conditions, provided residues are removed by purification and studied; the collection step should use a medium free of serum and serum substitutes, with defined composition. This article reviews the evidence, sets out four things to fix when switching from expansion to collection, and gives four methods for assessing the background and residue of medium-derived particles.

Downstream purification: recovery multiplies upstream cost

Cell debris, protein aggregates and extracellular-matrix components in conditioned medium foul filters, and that is the root of heavy EV losses downstream. RoosterBio Agent V-DSP is added at 1 mL per litre of medium and incubated for 30 minutes at room temperature before downstream processing; within the complete RoosterBio system, cumulative recovery reaches 40%–70%. Viscous, protein-rich culture supernatant can follow the IZON route: dilute and clarify, concentrate and buffer-exchange with qEV TFF, then remove protein on qEV220 SEC, giving about 15-fold higher purity, about 96% protein removal and consistent elution over 20 consecutive runs. Choose the SEC column format by processed loading volume, then the pore size (20, 35 or 70 nm) by purity requirement.

Characterization: measure size, concentration, charge and morphology separately, then cross-check

TRPS, DLS, NTA, nFCM and TEM each see a different side of the particles: DLS quickly gives the population's average size and PDI but weights large particles heavily; NTA tracks Brownian motion particle by particle; nFCM detects small vesicles of 40–50 nm and links them to surface markers; TEM shows morphology directly; TRPS measures size, concentration and zeta potential particle by particle from an electrical signal, independent of optical properties. By changing nanopores the iZON Exoid platform covers about 40 nm–10 μm, and samples can be fully recovered for cross-checking by NTA, nano-flow or TEM; in a four-mode standard comparison, TRPS resolved all four particle populations, while NTA missed one and MADLS could not resolve them.

  • One exosome sample, three sizes from DLS, NTA and TRPS — which do you trust? The five EV characterization techniques explained, and iZON Exoid measuring size, concentration and single-particle zeta potential in one run

    EVs are highly heterogeneous in size, morphology, concentration and molecular composition, so a single technique rarely gives a reliable answer; MISEV2023 recommends that physical characterization use at least two complementary techniques for orthogonal validation. This article compares the five mainstream exosome characterization techniques — TRPS (tunable resistive pulse sensing), DLS (dynamic light scattering), NTA (nanoparticle tracking analysis), nFCM (nano-flow cytometry) and TEM (transmission electron microscopy) — explaining what each measures and how to combine them. iZON Exoid uses the electrical TRPS principle to obtain true particle size, particle concentration and single-particle zeta potential simultaneously in one run, can baseline-resolve 4–6 polydisperse particle populations, covers about 40 nm–10 μm by changing elastic nanopores, and returns the sample intact for cross-validation by NTA, nano-flow cytometry or TEM.

  • Why choose Exoid: TRPS baseline-resolved all four populations of a quadrimodal standard and measures size and zeta potential particle by particle from 35 µL

    Two things hurt EV, LNP and viral-vector characterization most: averages that hide subpopulations and optical methods that miss aggregates. IZON Exoid uses tunable resistive pulse sensing (TRPS) to measure particles one by one through physical impedance rather than light: with a quadrimodal standard it cleanly separated all four particle populations, while NTA missed one and MADLS could not resolve them. Four reasons explain Exoid's accuracy, particle-by-particle output, real-time analysis and tunable range, and how it is used for EVs, LNPs, viruses and nanomedicines.

  • Is this batch of exosomes any good? One group stopped measuring molecules and started looking at the shape of cells

    Exosomes are not like a small-molecule drug, where measuring content tells you whether the batch passes. The characterisation used today — size, particle count, protein content, surface markers — confirms that the material is an extracellular vesicle without telling you whether the batch is active. That is not an outside criticism; it is a problem the field has stated about itself. A 2024 study in the Journal of Biological Engineering took a direct approach: activate human microglia with inflammatory cytokines and they grow larger and more complex; add mesenchymal stromal cell exosomes at the same time and, 24 hours later, their shape sits much closer to the unstimulated state. The team compressed 21 morphological features into a single composite score and tested its reliability with the quality metric used in drug screening — comparing the unstimulated and stimulated control groups, it cleared the bar in seven of eight experiments (that is how well the two controls separate, not a pass rate for EV batches). This article sets out what the method measures, why it sits closer to potency than molecular assays do, and what it still cannot answer.

One Exosome Sample, Three Sizes from DLS, NTA, TRPS: Which to Trust?

Watch on YouTube ↗
Video transcript

One tube of exosomes, three methods, DLS, NTA and TRPS, and three different sizes. Which one do you trust? Don't blame the instruments yet. Usually none of them is off. They simply look at particles in different ways. Exosomes vary widely in size, shape, concentration and molecular make-up.

That is why the MISEV2023 guidelines recommend at least two complementary techniques for physical characterization. Today, we take five methods apart, one by one. First, DLS, dynamic light scattering. A laser lights the whole sample, and the flicker of the scattered light gives the average hydrodynamic size of the whole population, plus a polydispersity index, PDI.

It is an intensity-weighted average over all particles, not single particles, so a few large particles or aggregates can easily carry more weight. The upside is speed, which suits high-throughput screening. NTA, nanoparticle tracking analysis, tracks every particle's Brownian motion frame by frame with a microscope and a high-speed camera, then sizes each one. Big and small count equally, and you get both a size distribution and a concentration.

But it relies on light. Whether a particle is seen at all depends on its refractive index and the detection threshold. TRPS, tunable resistive pulse sensing, uses electricity instead of light. Particles pass one by one through a tunable, stretchable nanopore, and each one makes the current dip for a moment.

One pulse, three readings. How deep it dips tracks particle volume, which gives size. How many pass per unit time gives concentration. How long each pulse lasts relates to surface charge, which gives a single-particle zeta potential.

It doesn't depend on how brightly a particle scatters light, so particles with different optical properties are easier to compare. The catch: choose the right nanopore and calibrate with reference particles. Nanoflow cytometry, nFCM, lines particles up single file and reads scattered light plus several fluorescence colors at once, linking each particle to surface markers so you can see the marker-positive subpopulations.

It can detect vesicles as small as 40 to 50 nanometers, though the lower limit varies with instrument, sample and labeling. TEM, transmission electron microscopy, shows shape directly. With negative staining you can see the typical cup-shaped double membrane.

But that cup shape depends on sample prep, and one field of view says nothing about overall concentration. Put them side by side. DLS sees the population, NTA sees single particles by light, TRPS sees single particles electrically, nFCM links them to markers, and TEM shows structure. Different views, different numbers, and they fill each other's gaps.

Combine by question. Use TRPS or NTA for size and concentration, nFCM or other marker analysis to link particles to identity markers, and TEM for shape. Then you can tell whether a process change affected particle numbers, subpopulations or structure.

A quick note on an instrument we sell: iZON's Exoid, which uses TRPS. According to the manufacturer, one run gives size, concentration and single-particle zeta potential together, with baseline separation of 4 to 6 polydisperse particle populations.

The manufacturer also says that with different nanopores, the platform covers about 40 nanometers to 10 micrometers overall. That is not the range of one pore in one run. Samples can be recovered afterwards for cross-checking by NTA, nFCM or TEM.

It isn't meant to replace other techniques, but to make your existing optical and molecular evidence more complete. Hold on, one thing to remember: no single method can confirm that a particle is an EV. Key conclusions need orthogonal methods built on different principles, and results also depend on sample matrix, instrument settings and calibration.

The quick-reference table and references: the TechWave technical column at techwave.hk.

Is this batch of exosomes any good? One group stopped measuring molecules and started looking at the shape of cells

Watch on YouTube ↗
Video transcript

Two vials look identical. Would you bet that they do the same job? With extracellular vesicles, making more is only half the story. The harder question is what this particular batch can actually do. Not so fast. Size, particle count and markers are essential clues to identity and composition. But a parcel with the right dimensions has not yet shown that its contents can do the job.

And one positive marker cannot establish that every vesicle is an exosome. Here we mean extracellular vesicles from mesenchymal stromal cells, or MSC EVs. What we still need is a ruler for function. Surprisingly, that ruler can start with cell shape. In 2024, Daga and colleagues used C20, an immortalised human microglia cell line, as their reporter system. These were not primary cells or a human trial.

Picture three separate wells taking the same test. The first is untreated. The second gets interferon gamma and tumour necrosis factor alpha, at five nanograms per millilitre each. The third gets those same cytokines and EVs at the same time.

After twenty four hours, the cells are fixed, stained and imaged. This is not one cell being activated and then rescued by EVs. We are comparing endpoint images from three different wells. With cytokines alone, the cells have larger, more complex outlines. With EVs present from the start, their shape sits closer to the untreated group. This is not a beauty contest: software traces the cell and nuclear boundaries.

Next, twenty one cellular and nuclear shape features become one composite score. Think of a dashboard rather than twenty one separate dials. It summarises the morphological response in this cell system, not every possible EV function.

But seeing a change does not automatically give you a useful ruler. If unstimulated and stimulated scores overlap too much, noise can hide the difference. A screening assay needs to separate those controls clearly. The team checked this with the Z factor: seven of eight experiments scored above zero point five. That tests separation of the controls. It does not mean seven EV batches passed, or that this is an approved release test.

Keep two findings separate. The morphological difference between controls did not differ significantly across experiments or operators. Separately, the EV associated shift repeated across independently manufactured EV batches. One tests the ruler; the other tests whether the trend repeats.

Now for the twist. Does immune modulation mean turning every signal down? Among the measured secreted factors, fourteen decreased and twelve increased. That looks more like rearranging an orchestra than turning the master volume to zero.

Author's note: the video follows the paper's abstract in saying that 14 secreted factors decreased and 12 increased. The paper's Results section and Figure 7 give 14 decreased and 10 increased among 24 differentially secreted proteins, and the article text follows the Results. The two counts are the paper's own differing figures; the video's point stands: secretion goes both down and up rather than being lowered across the board.

The researchers also examined proteins and mitochondrial shape, adding other angles on the response. These are still activity clues from a cell experiment. Change the donor, process or target cell, and the ruler needs validation again.

For transparency, the study used RoosterBio media for MSC expansion and EV collection. Those are experimental materials, not a substitute for the functional result. TechWave sells related products; the findings belong to the study.

So next time someone shows you a particle count and asks whether the batch is good, pause. What do you want it to do, and which functional readout will show it? Look beyond the cargo to what the vesicles do to cells. Find the full article and references in the TechWave technical column.

Five EV characterization methods at a glance
MethodMain outputKey difference for method selection
TRPSElectrical size, concentration, single-particle zeta potentialIndependent of scattering brightness; needs a suitable nanopore and calibration
DLSPopulation-average hydrodynamic size, PDIFast screening, but a few large particles can sway the intensity-weighted result
NTASize distribution and concentration from single-particle tracksDistributions compare directly; optical visibility affects which particles are counted
nFCMScatter, concentration and fluorescent-marker subpopulationsLinks particle features to molecular markers; background must be controlled
TEMMorphology, membrane structure and imaged sizeDirect structural evidence; sample preparation and field choice affect interpretation

Frequently asked questions

DLS, NTA and TRPS give different sizes for the same EV sample. Which one is right?

Usually no instrument is wrong; they measure particles differently: DLS gives an intensity-weighted population average, NTA relies on optical tracking and TRPS on electrical blockade. MISEV2023 recommends orthogonal verification with at least two complementary techniques, and combining methods by question is more reliable than trusting one number.

Why is EV downstream recovery so low?

Mainly filter fouling: cell debris, protein aggregates and extracellular-matrix components in conditioned medium block the membranes, and cumulative downstream particle recovery in conventional processes is only 5%–10%. RoosterBio pretreats with Agent V-DSP to relieve fouling, reaching 40%–70% cumulative recovery within the complete RoosterBio system.

How do I choose the pore size of a qEV SEC column?

Choose 35 nm for broad recovery and 70 nm to reduce lipoprotein interference; the latter removes about 99% of ApoB from plasma. With Gen 2 resin, EV particles per μg of total protein average 2.6 times the legacy column at 70 nm and 4.6 times at 35 nm.

Which quality attributes should be checked after EV scale-up?

The RoosterBio and Sartorius 15 L scale-up study looked at cell-density and particle-concentration curves, membrane-stain-positive fraction, size distribution, CD63/CD9/CD81 and TSG101 markers, and bioactivity in a HUVEC scratch assay. Particle count alone does not show that quality is unchanged after scale-up.