MSC extracellular vesicles from 3D culture are not just more numerous: more varied in composition and stronger at promoting neurite growth in vitro

Moving mesenchymal stromal cells (MSCs) from flasks into a bioreactor brings one obvious change: many more vesicle particles in the harvest. But are the extra vesicles the same kind as before? A 2022 study in Stem Cell Research & Therapy compared 2D and 3D culture of bone-marrow MSCs from 3 donors. EV concentration in 3D was 24 to 28 times that in 2D, though the difference did not reach statistical significance, which the authors attribute probably to the small number of repeats. More notably, 3D-derived EVs had a visibly more varied surface-marker make-up and promoted neurite growth more strongly in mouse trigeminal ganglion neurons (average neurite length 3301.5 μm versus 1860.5 μm). This article takes apart those three layers of change and the questions the study leaves open.

Definition

Extracellular vesicle (EV) heterogeneity means that vesicles released by cells of the same origin are not uniform in size, surface proteins or cargo, and can be divided into several subpopulations. The three tetraspanins CD9, CD63 and CD81 are commonly used in EV characterisation and, through their combinations, to distinguish subpopulations. When culture conditions change, the make-up of the EV population can change with them, which is one reason a process change calls for fresh characterisation.

Move mesenchymal stromal cells (MSCs) from flasks into a bioreactor and the first change you usually see is a sharp rise in the number of vesicle particles in the harvest. For many teams the conclusion stops there: 3D culture means higher yield.

But what if the extra vesicles are not the same thing as before?

In 2022, Jalilian and colleagues at the University of Illinois Chicago published a study in Stem Cell Research & Therapy that takes this question apart (reference 1). They grew the same bone-marrow MSCs either in flasks or in a vertical-wheel bioreactor, collected extracellular vesicles (EVs) in the same collection medium, and compared three things: particle concentration, composition and effect on nerve cells. All three differed: the difference in particle concentration did not reach statistical significance, while the differences in composition and effect are the more notable.

How the study was designed

  • Cells: bone-marrow MSCs from 3 human donors, passages 3–5, expanded with the RoosterBio High Performance Media Kit (KT-016).
  • 2D arm: T75 flasks seeded at 13,000 cells/cm² (1.3E4 cells/cm²) and grown for 72 hours to about 80% confluence before the switch to collection medium.
  • 3D arm: a PBS Biotech 0.1 L vertical-wheel bioreactor with 1.25 g of low-concentration Synthemax II microcarriers, seeded at 4,600 cells/cm² with expansion medium brought to 90 mL after cell attachment; agitation started at 25 rpm and was raised to 35 rpm with a feed after 72 hours, and the switch to collection medium came on day 5.
  • Collection: both arms were switched to the chemically defined RoosterCollect-EV (M2001) for a 72-hour collection, and EVs were isolated by ultracentrifugation.
  • Readouts: nanoparticle tracking analysis (NTA) for particle concentration and size; ExoView single-vesicle analysis for the surface markers CD9, CD63 and CD81; and a functional assay in mouse trigeminal ganglion neurons, with βIII tubulin staining, neurite length quantified in Neurolucida, and branching complexity assessed by Sholl analysis.

Why trigeminal ganglion neurons? Corneal nerves come from the ophthalmic branch of the trigeminal nerve, and isolating corneal nerves directly is difficult, so the researchers used trigeminal ganglion neurons as an in-vitro model. The group's end goal is repair of corneal nerve injury.

First change: more than twenty times the concentration, but not statistically significant

By NTA, EV concentration in the 3D arm was 24 to 28 times that of the 2D arm (the paper reports each figure in a different section). The gap looks large, but it did not reach statistical significance, which the authors in their discussion attribute probably to the small number of repeats (n = 4). This compares particle concentration per unit volume and cannot be converted directly into total batch yield.

Size distributions differed as well. Most 2D-derived EVs were 60–180 nm, with a smaller population of larger particles at 300–400 nm; most 3D-derived EVs were 50–170 nm, with a smaller peak at 200–300 nm and a very small one near 400 nm. Mean diameters were 139.13 nm and 146.86 nm respectively.

By the end of collection, cell number had increased 6.9 ± 3.7-fold in 3D and 3.8 ± 0.8-fold in 2D, a statistically significant difference. Bear in mind that the two arms differed in both seeding density and the length of expansion before the switch to collection medium.

The authors also flag a limitation of NTA itself: in a mixed population of different sizes, small particles can be masked by the signal from larger ones, which affects both concentration and size. That is why they added a finer layer of analysis with ExoView.

Second change: vesicles from 3D culture are more varied in composition

CD9, CD63 and CD81 are three tetraspanins commonly found on the EV surface and are commonly used in EV characterisation. Within one sample, though, different vesicles carry different combinations, and those combinations define subpopulations.

ExoView showed that both arms consisted mainly of CD63-positive vesicles, but the 3D arm had a marked increase in the concentration of CD81- and CD9-positive vesicles. It was not only a matter of numbers: the mean fluorescence intensity of CD81- and CD9-positive particles was also significantly higher, which the authors take as indicating more epitopes of these two proteins on each vesicle.

Then the combinations: among CD63-captured vesicles, the share positive for all three of CD63, CD81 and CD9 rose from 1.4% in 2D to 6.2% in 3D (these percentages come from representative data on a single chip). The authors read this as a more heterogeneous EV population from 3D culture. Label-free interferometric sizing showed no significant difference in size between particles carrying the different markers in the 50–200 nm range.

What this layer means: moving from flasks to a bioreactor may give you not just more of the same vesicles, but a differently composed product. Identity characterisation done under 2D conditions cannot simply be carried over to a 3D process.

Third change: 3D-derived EVs promoted neurite growth more strongly in vitro

The functional assay used trigeminal ganglion neurons from 3–5-week-old BALB/c mice. Once the neurons had attached and begun to extend thin neurites, EVs were added, and the cultures were followed to day 5.

EVs from both arms promoted neurite growth and branching; EV-depleted medium did not, indicating that the effect was associated with the EV-enriched fraction pelleted by ultracentrifugation rather than with the supernatant; this control cannot, however, separate EVs themselves from other material that pellets with them.

The difference between the arms was also clear. Quantified by βIII tubulin staining on day 5:

  • Average neurite length: 3301.5 μm with 3D EVs and 1860.5 μm with 2D EVs (P < 0.05);
  • Total neurite length: 14,588.2 μm with 3D EVs and 2,243.96 μm with 2D EVs (P < 0.05);
  • Sholl analysis: within the 50–120 radius range reported in the paper, neurons treated with 3D EVs had significantly more branch intersections than those treated with 2D EVs or the control.

Neurite length quantification used 4 biological replicates with 16 technical replicates per condition; the Sholl curves came from 3 independent experiments.

What the study does not yet answer

Why do 3D-derived EVs work better? The authors set out three possibilities for future work: a higher EV concentration, more epitopes on each vesicle, or a particular subpopulation, which might be purified further, doing most of the work.

The study's boundaries also matter: in-vitro data only, 3 donors, and few repeats in the EV concentration comparison. It is best read as a clear signal rather than a settled conclusion.

What came next: the same group's 2026 study

This line of work was later taken further. In 2026, Massoumi and colleagues from the same group published an extended study in Small (reference 2): 5 donors, corneal as well as bone-marrow MSCs, an in-vivo mouse model and miRNA sequencing. The results pointed the same way, and the concentration difference reached statistical significance (p < 0.05); in vitro, neurite length was 10.21 ± 1.24 mm with 3D bone-marrow MSC-EVs and 3.0 ± 0.32 mm with the corresponding 2D EVs. That study also found no marked difference in EV output per cell between groups; the advantage of 3D lay in higher harvest concentration and stronger potency. We cover that study in detail in a separate article on vertical-wheel 3D culture of corneal MSC-EVs.

What this means for MSC-EV process development

  • Yield is not the only thing that changes when you move from 2D to 3D. The surface-marker make-up of the EVs may change too, so identity characterisation needs to be repeated.
  • Particle counts alone do not tell you how active a batch is. Comparing processes or batches needs a functional readout; we describe an MSC-EV potency assay based on microglial morphology in a separate article.
  • For process comparability, number, composition and function can sit in the same plan as three dimensions of comparison, alongside other critical quality attributes.

About the products referred to in this article

The study cited here used the RoosterBio MSC High Performance Media Kit (KT-016) and the chemically defined EV collection medium RoosterCollect-EV (M2001), with a PBS Biotech vertical-wheel bioreactor for 3D culture.

TechWave Biotech supplies the RoosterBio range of MSC expansion and EV collection media and PBS Biotech vertical-wheel bioreactors. Specifications, grades and intended scope follow the manufacturer's product documentation; please contact us for details.

References

  1. Jalilian E, Massoumi H, Bigit B, et al. Bone marrow mesenchymal stromal cells in a 3D system produce higher concentration of extracellular vesicles (EVs) with increased complexity and enhanced neuronal growth properties. Stem Cell Research & Therapy, 2022, 13: 425. DOI: 10.1186/s13287-022-03128-z
  2. Massoumi H, et al. Corneal Nerve Regeneration via MSC-Derived EVs: Tissue Source and Culture Dimensionality Dictate miRNA Cargo and Therapeutic Efficacy. Small, 2026, 22(6): e07451 (Epub 2025 Dec 3). DOI: 10.1002/smll.202507451

Uses and applicable scenarios

  • Deciding which measures beyond yield to compare when moving MSC-EV production from flasks to a bioreactor
  • Designing an EV comparability plan between 2D and 3D processes that looks at number, composition and function together
  • Interpreting shifts in tetraspanin combinations in single-vesicle data such as ExoView
  • Choosing an in-vitro functional readout for MSC-EV studies with a nerve-regeneration endpoint

Limitations

  • In vitro only, using mouse trigeminal ganglion neurons; no in-vivo data and no human data
  • Bone-marrow MSCs from only 3 donors; the EV concentration comparison had 4 repeats, and the 24- to 28-fold difference was not statistically significant
  • Seeding density and the length of expansion before collection differed between the 2D and 3D arms, which should be kept in mind when comparing cell expansion
  • The triple-positive percentages come from representative data on a single chip
  • Why 3D-derived EVs work better (vesicle number, surface protein per vesicle, or a particular subpopulation) has not been determined

Frequently asked questions

Does 3D culture yield more EVs because each cell secretes more?

Current evidence does not support that reading. The same group's 2026 extended study found no marked difference in EV output per cell between groups; the advantage of 3D lay in higher harvest concentration and stronger potency. In the 2022 study, cell expansion was greater in 3D (6.9 ± 3.7-fold versus 3.8 ± 0.8-fold), and EV concentration was 24 to 28 times that in 2D, but this was not significant, probably because of the small number of repeats (n = 4) according to the authors; the concentration difference reached statistical significance in the 2026 study.

Do EV surface markers change when moving from flasks to a vertical-wheel bioreactor?

In this study they did. ExoView showed a marked increase in CD81- and CD9-positive vesicles from 3D culture, with higher mean fluorescence intensity of particles positive for either marker; among CD63-captured vesicles, the share positive for all three markers rose from 1.4% to 6.2% (representative data from a single chip). After a change of culture format, EV characterisation should therefore be repeated rather than carried over from 2D data.

Does EV-depleted medium affect neurites? Could the medium itself be responsible?

Not the supernatant medium. The study used collection medium with EVs removed by ultracentrifugation as a control, and it had no effect on neurite growth or branching, whereas EVs from both 2D and 3D culture promoted neurite growth, more strongly from 3D. The effect was therefore associated with the EV-enriched fraction pelleted by ultracentrifugation rather than the supernatant, although this control cannot separate EVs themselves from other material that pellets with them.

Do these data show that 3D-derived MSC-EVs can treat corneal nerve injury?

These in-vitro data cannot show that. The study has in-vitro data only, using mouse trigeminal ganglion neurons, with no in-vivo work and no human data. What it shows is that, under this study's conditions, 3D-derived EVs differed from 2D-derived EVs in composition and in activity in this model, with a trend towards higher particle concentration, which is useful when choosing a culture system or designing a functional assay.