Products

PhysioMimix® Core Microphysiological System

CN Bio PhysioMimix Core modular human microphysiological system (MPS): a benchtop instrument for single-organ, higher-throughput and multi-organ studies, running up to 6 multi-chip plates and 288 samples per controller.

Product information

Brand
CN Bio Innovations
Catalog no.
PhysioMimix
Specification
Unit

PhysioMimix Core organ-on-chip system

Organ-on-chip analysis is regarded as a key element of faster, more precise drug development and precision medicine. It gives a better understanding of disease and improves the development of new therapies by studying human cells and tissues, providing precise, physiologically relevant preclinical data without expensive, time-consuming animal studies. Organ-on-chip research lets scientists focus on drug targets, toxicity mechanisms and drug interactions, moving drugs into clinical trials while avoiding costly failures.

Physiological relevance has long driven the use of primary cells and stem cells in in vitro assays. PhysioMimix makes it quick and easy to create 3D tissue mimics with automated microfluidic control for long-term cell culture and information-rich analysis. Choosing the right cells is a factor in experimental success, and maintaining cell phenotype matters greatly for studying complex biological processes, intra- and inter-organ interactions, autocrine/paracrine factors and responses to pathogens and xenobiotics.

PhysioMimix organ-on-chip is compatible with a wide range of primary cells, stem cells and cell lines, giving flexibility for your research needs. Whether you want to get more out of an existing culture system or are taking on complex multi-organ studies, the combination of PhysioMimix hardware, consumables and assay templates makes organ-on-chip easy to start.

Features

  • Benchtop all-in-one instrument: compact and compatible with existing lab equipment; one instrument runs single-organ, higher-throughput and multi-organ experiments.
  • Easy to use: set up and start a run within 1 minute.
  • Open-well design: supports the move from 2D to 3D culture; for example, commercial Transwell inserts fit easily into the barrier-chip chambers.
  • Monitoring during culture: samples can be taken for analysis.
  • Programs can be saved: long-term automated experiments with less user input.
  • Tissues and cells: compatible with a range of pre-formed tissues and cell types.
  • Multi-organ: two organs connected by microfluidics to study crosstalk.
  • Lower cost per chip: 12-well and even 48-well plate designs mean more wells per experiment and lower cost.
  • Higher data confidence: several control or replicate wells on one plate.
  • Earlier insight: higher throughput and processing capacity than other devices bring insight earlier in the process.

Applications

  • Organoid and organ models: liver, gut, lung, kidney, brain and more, single-organ or multi-organ
  • Disease models: NASH, hepatitis B (HBV), oncology, pneumonia (COVID-19) and more
  • Safety toxicology: drug-induced liver injury (DILI), immune-mediated toxicity, genotoxicity and more
  • ADME/pharmacology: drug absorption, drug metabolism, bioavailability and more

Key publications

Disease models

  • [Infectious disease] Ortega-Prieto AM et al. 3D microfluidic liver cultures as a physiological preclinical tool for hepatitis B virus infection. Nat Commun. 2018; 9: 682.
  • [Diabetes and NASH] Kostrzewski T et al. Three-dimensional perfused human in vitro model of nonalcoholic fatty liver disease. World J Gastroenterol 2017; 23(2): 204-215.
  • [Oncology] Wheeler SE et al. Spontaneous dormancy of metastatic breast cancer cells in an all-human liver microphysiologic system. Br J Cancer 2014; 111(12): 2342-2350.

Multi-organ systems

  • [2-Organs] Chen WL et al. Integrated Gut/Liver Microphysiological Systems Elucidates Inflammatory Inter-Tissue Crosstalk. Biotechnology and Bioengineering, 2017; 114(11): 2648-2659.
  • [2-Organs] Dalrymple A et al. The characterization of a human two Organ-on-a-Chip (lung-liver) system which has the potential to measure systemic responses in vitro. Poster presented at Society of Toxicology 57th Annual Meeting; 2018 Mar 11-15: San Antonio, Texas.
  • [4/7/10-Organs] Edington et al. Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies. Sci Rep 2018; 8: 4530.

Drug development

  • [Drug Safety] Long TJ et al. Modeling Therapeutic Antibody-Small Molecule Drug-Drug Interactions Using a Three-Dimensional Perfusable Human Liver Coculture Platform. Drug Metab Dispos 2016; 44(12): 1940-1948.
  • [Drug Metabolism] Vivares A et al. Morphological behaviour and metabolic capacity of cryopreserved human primary hepatocytes cultivated in a perfused multiwell device. Xenobiotica 2015; 45(1): 29-44.
  • [Drug Metabolism] Tsamandouras N et al. Quantitative Assessment of Population Variability in Hepatic Drug Metabolism Using a Perfused Three-Dimensional Human Liver Microphysiological System. J Pharmacol Exp Ther 2017; 360(1): 95-105.

Frequently asked questions

1. What is PhysioMimix Core?

A modular human microphysiological system (MPS) developed by CN Bio for building single-organ and multi-organ in vitro models that more faithfully mimic human physiology and pathology.

2. Which studies can be run?

Drug metabolism and pharmacokinetics (ADME/PK), toxicology (such as DILI, genotoxicity and organ-specific toxicity), drug absorption and bioavailability, disease modelling, efficacy evaluation, immunology and multi-organ interaction studies.

3. Which cells are supported? Can animal-derived cells be used?

Primary cells, cell lines, iPSC-derived cells and tissue samples. The open design also allows animal-derived cells, so cross-species comparison studies are possible.

4. Can it be used for multi-organ and immune studies?

Yes. The system supports interconnected organ models such as gut–liver and lung–liver to study inter-organ interactions; tissue-resident or circulating immune cells can also be added to organ models to study drug-induced immune responses and immunotoxicity.

5. Can it be used for bioavailability studies?

Yes. Connecting gut and liver models simulates drug absorption and first-pass metabolism together for in vitro bioavailability studies.

6. Which drug modalities are suitable?

Small molecules, large molecules, ASOs, siRNA, AAV and other gene-therapy-related drugs.

7. What throughput is possible?

It depends on the multi-chip plates used: one controller can run up to 6 multi-chip plates at the same time, supporting up to 288 samples.

8. Is it hard to learn? Does it need external pumps?

The modular design needs no complex microfluidic engineering experience, and installation is usually completed within 1 hour. Flow control is integrated, so normal use requires no external pumps or complex flow-control equipment.

9. What are the chips made of?

The multi-chip plates are made of COC (cyclic olefin copolymer), which can reduce non-specific absorption of some small-molecule drugs compared with conventional PDMS.

10. Is long-term culture possible?

Yes. With suitable cells, media and experimental conditions, it supports longer-term tissue culture and maintenance of function, suiting drug and disease studies that need long observation.

11. Can it replace animal studies?

PhysioMimix Core is an important complement to animal studies and can help reduce the need for some of them; whether it can replace them must be assessed according to the research aim, the degree of model validation and the specific application.

12. How does it differ from ordinary organ chips?

It does not just provide a microfluidic environment: it integrates organ models, dynamic perfusion, modular chips and multi-organ connection in one system while balancing ease of use and throughput, which suits drug development and research on complex human physiological models.