Products
PhysioMimix® Dual-organ Plate (MPS-TL6)
PhysioMimix Dual-organ Plate (TL6): six two-organ systems per plate linking a barrier model with 3D liver by fluid flow, for oral bioavailability, absorption–metabolism and multi-organ toxicity studies.
Product information
- Brand
- CN Bio Innovations
- Catalog no.
- TL6
- Specification
- Plate
Features of the TL6 multi-organ chip
- Six in vitro multi-organ systems can be built in parallel; in each, two organs are connected by fluid to model inter-organ interactions accurately.
- Integrates a barrier model (gut or lung chip) with a 3D liver chip, closely recreating the human physiological microenvironment.
- High human relevance, as an alternative to animal experiments, improving the reliability of clinical-translation predictions.
- Compatible with primary cells, iPS cells, organoids, tissue slices and other cell types for many research scenarios.
- Focused on drug absorption, metabolism and bioavailability, supporting key pharmacokinetic evaluations.
Frequently asked questions
1. What is the Dual-organ Plate, and how many models fit on one plate?
A multi-chip plate for building two-organ in vitro models: two different organ models are connected by fluid to study the interactions between organs. Each plate can host 6 independent two-organ systems at the same time, each with two interconnected organ models.
2. Which organs can be connected?
Currently mainly barrier organ models connected to a liver model, such as gut/liver and lung/liver; other two-organ models can be developed to suit the research question.
3. How do the two organs "talk" to each other?
The two organ models are cultured in separate compartments connected by a fluid path. The medium circulates between them, so metabolites and secreted factors from one organ can act on the other, mimicking the blood-borne exchange of substances between organs in the body.
4. Which drug studies can be run?
A gut/liver chip models intestinal absorption and hepatic metabolism together and is particularly suited to oral-bioavailability studies. It can also be used to study absorption and transport across the gut barrier followed by liver metabolism, as well as multi-organ toxicity and immune-mediated toxicity that are difficult to observe in single-organ models.
5. Which cells are used?
Primary cells, iPSC-derived cells, immortalised cell lines, circulating immune cells, precision-cut tissue slices and organoids are supported. The liver side can use primary human hepatocytes (PHH) and co-cultures; the barrier side can use epithelial or endothelial cells chosen for the study, building multicellular barriers on the apical and basolateral sides of a Transwell insert.
6. Can immune cells be added?
Yes. The system supports circulating immune cells for studying how immune cells interact with organ tissue and immune-mediated toxicity.
7. Is the flow rate adjustable? Can the two organs use different media?
PhysioMimix Core can regulate the flow in each compartment and between the organs, setting flow conditions to the physiological needs of each organ. Because the two organs share a fluid environment, a compatible medium system that supports the function of both models is needed, chosen according to the cell types and protocol.
8. Can we use our existing organ models? What equipment is needed?
PhysioMimix multi-chip plates have an open design that allows flexible model adaptation and customisation, and some existing barrier models can be used with the Dual-organ Plate. The plate is used with the PhysioMimix Core system, which provides dynamic fluid circulation and control between the organs.
Related brands
Related products
Technical resources
- The UK plans to cut dog and non-human primate use in PK studies by 35% by 2030: how organ-on-chip is reshaping drug development
- FDA team's test: the same hepatotoxin gives EC50 values differing several-fold across liver MPS, spheroids and sandwich culture, with consistent results across two sites and two Kupffer cell lots
- Animal Models Predict Human Oral Bioavailability with an R² of Only 0.34? CN Bio's PhysioMimix Gut–Liver Chip: Better Predictions Than Animal Models for 3 of 4 Drugs, One MPS-TL6 Plate per Drug
- Selecting an HBV Liver Chip: 3D Perfused PHH Cultures Hold a Functional Window of 40 days and Secrete About 10 Times More Albumin Than 2D
- Mouse models miss full NASH and primary hepatocytes lose function in days? CN Bio PhysioMimix human liver-on-chip: primary hepatocytes in 3D culture for over a month, with steatosis, NASH and fibrosis models built on one device
- Are fatty-liver patients more prone to drug-induced liver injury? AstraZeneca's CN Bio PhysioMimix fatty-liver chip shows CYP2E1 activity up 2.5-fold after fat loading and worse injury from acetaminophen and ticlopidine
- Rat S9 a poor predictor of human genotoxicity? Charles River connects TK6 cells to a CN Bio liver-on-chip: comet and micronucleus assays in one system, with cyclophosphamide results matching in vivo studies
- For Solid-Tumour CAR-T, Killing Is Not Enough, It Has to Get There: A CN Bio PhysioMimix Perfused Melanoma Chip Reads Out Transendothelial Migration, Barrier Integrity and Tumour Killing in One Model
- Does GalNAc conjugation always mean higher uptake? A liver-on-a-chip test: ahead at 1 hour at 2 μM, overtaken by untargeted ASO at 10 and 50 μM after 1 hour
- Liver, gut, lung and kidney toxicity that 2D cytotoxicity misses, organ-on-chip catches earlier: intestinal organoids 78% sensitive versus 22% for Caco-2, MUC5AC loss before viability changes
- Organ-on-Chip Disease Modelling with PhysioMimix: MASLD Insulin Resistance, 40-Day Hepatocyte Function, HBV Research, CAR-T Migration and Dormant Breast Cancer Reawakening
- Nature Portfolio Perspective: Why Liver Chips Stay Immature, and How a Developmental Roadmap Rebuilds Them, With a Six-Layer Selection Guide
- Six Pharma Case Studies in Organ-on-Chip ADME: How CN Bio PhysioMimix Links Gut Absorption, Hepatic First Pass and Antibody DDI Into One Drug Journey