Technical column
Does GalNAc conjugation always mean higher uptake? A liver-on-a-chip test: ahead at 1 hour at 2 μM, overtaken by untargeted ASO at 10 and 50 μM after 1 hour
GSK's antisense oligonucleotide Bepirovirsen was approved in Japan in August 2026, and behind it lies a development story about using liver-on-a-chip to resolve cellular drug distribution. Teams from GSK, Ionis and the University of Illinois COMI co-cultured primary human hepatocytes and Kupffer cells at 10:1 in a CN Bio PhysioMimix perfused liver MPS and found that the advantage of GalNAc-ASO depends on time and dose: higher at 1 hour at 2 μM, overtaken by untargeted ASO by 4 hours, and lower in average uptake at 10 μM and 50 μM after 1 hour — pointing to receptor saturation.
Definition
A perfused liver microphysiological system (MPS) co-cultures primary human hepatocytes and Kupffer cells in 3D on a porous scaffold, with continuous flow creating nutrient and oxygen gradients, to study drug uptake and subcellular distribution across liver cell types.
Reaching the liver does not mean reaching the target cell. Combining a CN Bio PhysioMimix liver MPS with multimodal imaging resolves dose, time and cell identity together: GalNAc-ASO leads at 2 μM after 1 hour, while untargeted ASO leads in the 1-hour comparisons at 10 μM and 50 μM.
On 24 August 2026 GSK announced that its antisense oligonucleotide (ASO) drug Bepirovirsen (brand name Hibsago) had been approved by Japan's Ministry of Health, Labour and Welfare for functional cure in eligible adults with chronic hepatitis B (CHB): at least 6 months of prior nucleos(t)ide analogue therapy, HBsAg ≤3000 IU/mL and HBV DNA <90 IU/mL at treatment initiation — the drug's first approval worldwide and the first treatment approved in Japan for functional cure of chronic hepatitis B.
For drug developers, though, the more interesting part is the research behind it. GSK selected Bepirovirsen as a key ASO candidate in chronic hepatitis B back in 2018 and went on to study the cellular distribution of non-GalNAc versus GalNAc-conjugated ASOs. In 2019, GSK, Ionis Pharmaceuticals and the GSK Center for Optical Molecular Imaging (COMI) at the University of Illinois collaborated on studying ASO uptake and distribution using several nonlinear optical imaging techniques — and one key research tool was the CN Bio PhysioMimix liver-on-a-chip system.
The conclusion was unexpected: GalNAc conjugation does not always give higher cellular uptake. Its advantage depends on time and dose.

Figure 1. Official manufacturer image of the PhysioMimix Core; showing the appearance of this product family.
Why ASOs must be studied at the level of "which cells"
ASOs regulate gene expression by binding complementarily to specific RNA sequences. They are far more sequence-specific than small molecules, but development still has to answer a key question: once the drug reaches the tissue, which cells does it actually enter, and where does it go inside them?
This is not a simple "did it get into cells" question. Besides hepatocytes, the liver contains Kupffer cells, sinusoidal endothelial cells and other cell types, and studies show that ASO uptake in the liver is not uniform — non-parenchymal cells can become important drug sinks.
So what is really worth studying is a chain: drug concentration → cellular uptake → cell type → subcellular localisation → change over time. This is precisely what conventional 2D culture struggles to answer completely. A GSK poster comparing mouse macrophages with mouse hepatocytes showed that GalNAc conjugation affects uptake differently between these cell types, indicating that ASO cellular distribution cannot simply be inferred from a single-cell-type model.
From 2D cells to a 3D microenvironment that behaves like liver
The GSK team moved from single-cell-type systems to a 3D complex in vitro model (CIVM): in a published poster, researchers co-cultured primary human hepatocytes with Kupffer cells at a 10:1 ratio in 3D, added fluorescently labelled ASO at different concentrations after 7 days of continuous culture, and analysed uptake and distribution over up to 48 hours.
The design let them observe, at the same time:
- ASO uptake by Kupffer cells;
- ASO uptake by hepatocytes;
- differences between rounded and cuboidal hepatocytes;
- competitive distribution of ASO between cell types;
- spatial localisation of ASO within cells.
That 3D co-culture was performed on the CN Bio PhysioMimix organ-on-a-chip system. Cells grew not only on the scaffold surface but also along the inside of the pores, and the researchers used confocal, label-free CARS/SRS and light-sheet microscopy to observe ASO distribution and hepatocyte phenotype.
The 2024 study: is GalNAc really always better?
A 2024 study in Lab on a Chip took the question further. The team used CN Bio PhysioMimix to build a 3D perfused liver MPS of primary human hepatocytes (PHHs) and Kupffer cells (KCs) at a 10:1 ratio, cultured on a porous scaffold with continuously flowing medium creating nutrient and oxygen gradients closer to the liver microenvironment.
They then compared untargeted ASO with GalNAc-ASO at different concentrations and time points. The question was no longer whether ASO entered cells, but how fast, how much, into which cells, and whether the same trend holds at different concentrations.
Result: the advantage depends on time and dose
| Condition | Result |
|---|---|
| 2 μM, 1 hour after dosing | Average cellular uptake of GalNAc-ASO clearly higher than untargeted ASO |
| 2 μM, 4 hours after dosing | Overall uptake of untargeted ASO exceeded GalNAc-ASO |
| 10 μM, 1 hour after dosing | Average cellular uptake higher for untargeted ASO |
| 50 μM, 1 hour after dosing | Average cellular uptake higher for untargeted ASO |
The researchers suggest this may relate to saturation of the GalNAc-ASGPR-mediated uptake pathway at higher concentrations.
In other words, "targeted" does not necessarily mean higher cellular uptake at every time point, every concentration and in every cellular environment. This is exactly the kind of information a complex 3D model provides: quantitative analysis by multiphoton fluorescence imaging showed higher GalNAc-ASO uptake at early time points, but different uptake kinetics for the two ASOs as time and concentration changed.
What matters may not be "how much" but "into whom"
Looking only at average fluorescence intensity across the whole chip makes it easy to miss one thing: different hepatocytes may not take up ASO in the same way.
The 2024 study analysed cuboidal hepatocytes in the liver chip specifically: one hour after dosing, GalNAc-ASO uptake in cuboidal hepatocytes was clearly higher than untargeted ASO, and imaging showed the ASO signal concentrated near nucleus-like structures rather than spread evenly through the cytoplasm.
That means a liver-on-a-chip can tell us not only whether a drug entered the liver, but what kind of hepatocyte it entered and how it is distributed inside the cell.
Why 3D plus perfusion plus multiple cell types matters
Conventional 2D experiments can show whether a drug is taken up by cells, but they struggle to reproduce, at the same time, interactions between cell types, 3D tissue structure, nutrient and oxygen gradients, a dynamic fluid environment, and competitive uptake between different cells.
Through its porous scaffold and continuous perfusion, the PhysioMimix liver MPS lets hepatocytes and Kupffer cells form a more complex 3D microtissue environment. In the 2024 study, PHHs and KCs were seeded onto collagen-coated porous scaffolds and medium flowed continuously through the tissue structure during culture, creating an oxygen gradient, and ASO exposure and imaging studies were run on this model. Organ-on-a-chip thereby becomes an important bridge between 2D cell experiments, 3D complex in vitro models, animal studies and the clinic.
When seeing the drug matters as much as measuring it
The study points in another notable direction: multimodal imaging. Rather than relying on fluorescence alone, the researchers combined multiphoton microscopy, stimulated Raman scattering (SRS), simultaneous label-free autofluorescence multiharmonic (SLAM) imaging and light-sheet fluorescence microscopy, capturing drug distribution, cell morphology, chemical composition and 3D spatial information together.
SLAM imaging resolved cellular structures to a depth of about 150 μm within the pores of the liver chip, and light-sheet microscopy achieved complete 3D visualisation to about 250 μm.
What the Bepirovirsen approval signals
According to public information, GSK is advancing Bepirovirsen registration with regulators in China, the United States and Europe; the US FDA has accepted its NDA for priority review and granted breakthrough therapy designation, with a PDUFA goal date of 26 October 2026; this review schedule is not US marketing approval.
From a development perspective, though, the significance goes beyond one approval. As ASOs, siRNAs and other nucleic-acid drugs continue to enter the clinic, developers need an increasingly detailed understanding of distribution, cellular uptake and subcellular localisation in human-relevant tissue. The question is shifting from "Drug → Cell → Response" to "Drug → Tissue → Cell type → Intracellular distribution → Molecular response", which requires in-vitro models to preserve spatial information and cellular heterogeneity rather than report a single average.
The GSK series shows exactly that: from 2D cells, to 3D hepatocyte/Kupffer co-culture, to the CN Bio PhysioMimix liver MPS, and finally to multiscale analysis of ASO uptake and distribution combining multiphoton, SRS and light-sheet imaging — a research path closer to human physiology for evaluating ASO targeting, PK/PD, uptake mechanisms and candidate screening.
Research directions a liver MPS can support
For ASOs and other nucleic-acid drugs, a more human-relevant in-vitro system can be built around cellular uptake and distribution, targeted delivery efficiency, competition for drug between cell types, dose-time relationships, hepatic metabolism and toxicity, PK/PD studies, and candidate screening and mechanism work.
Application scope: the conclusions above come from specific doses, time points and cell types; fluorescent and label-free readouts still need orthogonal controls, and an in-vitro model does not prove clinical efficacy or human pharmacokinetics.
Let TechWave help you see where your nucleic-acid drug goes
If you are evaluating hepatic targeting efficiency for ASOs or siRNAs, or need uptake and subcellular distribution resolved at the level of cell type, contact TechWave. Based on your compound type, dose range and imaging needs, we can help map out applications of the CN Bio PhysioMimix liver MPS, discuss application information and selection requirements.
References
- Majer J, Alex A, Shi J, Chaney EJ, Mukherjee P, Spillman DR, Marjanovic M, Newman CF, Groseclose RM, Watson PD, Boppart SA, Hood SR. Multimodal imaging of a liver-on-a-chip model using labelled and label-free optical microscopy techniques. Lab on a Chip. 2024;24(19):4594–4608. doi:10.1039/d4lc00504j
Uses and applicable scenarios
- Cellular uptake and distribution studies of ASOs, siRNAs and other nucleic-acid drugs
- Dose-time evaluation of targeted delivery strategies such as GalNAc
- Analysing competitive uptake between liver cell types
- Multimodal imaging of 3D drug distribution
Limitations
- Conclusions are bounded by the specific doses, time points and cell types studied and cannot be generalised to all conditions
- Fluorescent and label-free readouts still need orthogonal controls, and in-vitro models do not prove clinical efficacy or human pharmacokinetics