Many drugs fail in preclinical development because of unexpected toxicity, often linked to species differences in hepatic biotransformation, yet current in vitro genotoxicity testing relies on induced rat S9 mix for metabolic activation. A Charles River team applied CN Bio liver-on-chip (LOC) technology to genotoxicity testing: 3D liver tissue built from primary human hepatocytes (PHH) or HepaRG cells was co-cultured with human lymphoblastoid TK6 cells in a Transwell, dosed at 0, 24 and 45 hours on the in vivo schedule, with comet assays in hepatocytes and micronucleus assays in TK6. In HepaRG-LOC, cyclophosphamide had little effect in the liver but increased micronuclei in TK6, directly matching in vivo studies — a result not seen in 2D or 3D spheroid models — and PHH-LOC metabolized the indirect mutagens CP and BaP more effectively.

Definition

Liver-on-chip genotoxicity testing co-cultures a 3D liver chip with human metabolic function (built from PHH or HepaRG cells) with human lymphoblastoid TK6 cells, so drug metabolic activation happens in the same system and genotoxicity is assessed by the comet assay (DNA strand breaks) and the micronucleus assay (chromosome or mitotic-apparatus damage).

Many drugs fail in preclinical development because of unexpected toxic effects, often linked to species differences in hepatic biotransformation. Yet current in vitro genotoxicity testing still uses "Induced rat S9 mix" as the metabolic-activation system in single cells and bacteria — a reagent made mainly from the S9 fraction of Sprague Dawley (SD) rat liver, rich in drug-metabolizing enzymes such as P-450, and in essence rat metabolism.

A research team at Charles River, an internationally known drug discovery and preclinical services laboratory, applied the liver-on-chip (LOC) technology of UK-based CN Bio to genotoxicity testing: human liver tissue and human lymphoblastoid TK6 cells were co-cultured in one system, with comet assays in hepatocytes and micronucleus assays in TK6. According to the team, this produced more human-predictive results for the first time, potentially helping to bridge the gap between in vitro and in vivo studies.

Overview of this study

CN Bio PhysioMimix and Charles River research context

CN Bio PhysioMimix and Charles River research context.

Study topic: integrating human lymphoblastoid cells (TK6) into a liver-on-chip for genotoxicity testing — following the trend to reduce animal experiments.

Figure 1: A liver-on-chip (LOC) may help bridge the gap between in vivo and in vitro studies

Figure 1. A liver-on-chip (LOC) may help bridge the gap between in vivo and in vitro studies.

Objective: rebuild a liver with human metabolic function on a chip

The study aimed to rebuild the 3D organ microenvironment of a liver-on-chip with human metabolic function, constructed from primary human hepatocytes (PHH) or HepaRG cells and co-cultured with human lymphoblastoid cells (TK6) for genotoxicity assessment.

Materials and methods: dosing on the in vivo schedule, reading both compartments

Figure 2 (part 1): Treatment schedule, co-culture plate and microphysiological system
Figure 2 (part 2): Schematic of liver-chip and TK6 co-culture and how each endpoint is measured

Figure 2. Materials and methods. (A) Treatment follows the same schedule as in vivo genotoxicity tests; (B) the plate used for the co-culture system; (C) the microphysiological system (MPS); (D) schematic of liver-on-chip co-culture with TK6 cells and how each assay is adapted to the system.

  • System: the LOC consists of primary human hepatocytes (PHH-LOC) or HepaRG cells (HepaRG-LOC) together with TK6 cells; both LOCs contain extracellular matrix, endothelial cells, PHH or HepaRG and Matrigel, maintained in CN Bio's organ-on-chip system, while TK6 cells are cultured on a Transwell and the two compartments can communicate.
  • Multiple endpoints: comet assay in hepatocytes (% tail DNA intensity) and micronucleus assay in TK6 cells by flow cytometry with the MicroFlow kit (Litron).
  • Dosing: both compartments were treated at 0, 24 and 45 hours with a negative control, the direct mutagen methyl methanesulfonate (MMS, 5 μg/mL) or the indirect mutagens benzo[a]pyrene (BaP, 10 μg/mL) and cyclophosphamide (CP, 50 μg/mL); ethyl methanesulfonate (EMS) served as the positive control.
  • Replication: three independent experiments were performed, collecting hepatocytes and TK6 cells.

Result 1: cell viability in the co-culture system

Figure 3: Viability of LOC single-cell suspensions and TK6 cells, and microscopy after 9 days of culture

Figure 3. Viability of single-cell suspensions obtained from the LOC (trypan blue staining) and flow cytometry of TK6 cells. Percentage viability for LOC built from HepaRG co-cultured with TK6 cells (A) and from PHH co-cultured with TK6 cells (B); NA = not applicable. Microscopy images of (C) HepaRG-LOC and (D) PHH-LOC after 9 days of culture under microfluidic flow.

Result 2: in the HepaRG liver chip, cyclophosphamide results directly match in vivo studies

The HepaRG liver-on-chip showed that data obtained with CP are directly related to in vivo studies described with the same assays: little effect in the liver (% Tail DNA) but a positive response in lymphoid TK6 cells (increased % MN). These findings were not seen in 2D or 3D spheroid models of HepaRG.

Figure 4: Comet assay and TK6 micronucleus results in HepaRG-LOC

Figure 4. Results from at least three independent experiments. (A) Comet assay results for HepaRG cells in HepaRG-LOC, DNA damage level (% Tail DNA); statistical analysis by one-way ANOVA followed by Dunnett's multiple comparison test: †p<0.05, ‡p<0.01, §p<0.001, ¶p<0.0001, ns = not significant. (B) Micronucleus assay results for TK6 cells in HepaRG-LOC, micronucleus frequency (% MN frequency); statistical analysis by t-test: †p<0.05, ‡p≤0.005, ¶p<0.001. (Note: the Figure 4A axis labels BaP as 50 μg/mL, whereas the methods, Figure 4B and Figure 5 give 10 μg/mL; the original does not explain the difference.)

Result 3: the PHH liver chip metabolizes indirect mutagens more effectively

In the liver chip built with primary human hepatocytes, the TK6 results showed that PHH-LOC metabolized the tested indirect mutagens (CP and BaP) more effectively; some activities in primary human hepatocytes were lower or higher, most likely reflecting differences between donors.

Figure 5: Comet assay and TK6 micronucleus results in PHH-LOC

Figure 5. (A) Results from at least three independent experiments: comet assay results in PHH-LOC, with statistical analysis by one-way ANOVA followed by Dunnett's multiple comparison test: †p<0.05, ‡p<0.01, §p<0.001, ¶p<0.0001, ns = not significant. (B) Micronucleus (MN) assay results in TK6 cells in the liver chip built with PHH, micronucleus level (% MN frequency); statistical analysis by t-test: †p<0.05, ‡p≤0.005, ¶p<0.001.

Conclusions: one system, two classes of genotoxicity endpoint

  1. According to the research team, this study reported the application of microphysiological systems (MPS) to genetic toxicology testing for the first time.
  2. Both microphysiological systems (HepaRG-LOC and PHH-LOC) showed metabolic capability and could assess two classes of adverse genotoxic outcome in one system: induced chromosome or mitotic-apparatus damage (micronucleus assay) and DNA strand breaks (comet assay).
  3. The study shows that microphysiological systems may be a promising tool to better bridge the gap between in vivo and in vitro studies and warrant further exploration in genetic toxicology.

Keep in mind that these results come from specific compounds, doses and experimental designs, and PHH results may reflect donor variation; the study adds evidence for genotoxicity assessment with human metabolism but does not directly replace tests required by current regulations.

Let TechWave help you bring human metabolism into genotoxicity testing

If your project needs to assess indirect mutagens that depend on metabolic activation, or you want to complement the rat S9 system with human liver metabolism and reduce animal testing, contact TechWave. Based on your compound types and endpoint needs, we can help evaluate CN Bio PhysioMimix liver-chip and co-culture approaches, provide technical documents and arrange a quotation.

References

  1. Mandon, M., Huet, S., Dubreil, E., Fessard, V., & Le Hegarat, L. (2019). Three-dimensional HepaRG spheroids as a liver model to study human genotoxicity in vitro with the single cell gel electrophoresis assay. Scientific Reports, 9, 10548. https://doi.org/10.1038/s41598-019-47114-7
  2. Recio, L., Hobbs, C., Caspary, W., & Witt, K. L. (2010). Dose-response assessment of four genotoxic chemicals in a combined mouse and rat micronucleus (MN) and Comet assay protocol. The Journal of Toxicological Sciences, 35(2), 149–162. https://doi.org/10.2131/jts.35.149

Uses and applicable scenarios

  • Genotoxicity assessment of indirect mutagens that require metabolic activation
  • In vitro testing that replaces or complements rat S9 mix with human liver metabolism
  • Multi-endpoint evaluation with comet and micronucleus assays in one system
  • Genetic toxicology studies that reduce animal testing

Limitations

  • Results come from specific compounds (MMS, BaP, CP, EMS), doses and at least three independent experiments; PHH results may reflect donor-to-donor variation
  • The research team concludes that MPS may be a promising tool that warrants further exploration in genetic toxicology; it does not directly replace current regulatory tests