Products
Akura™ Twin Organ-on-Chip Platform Starter Kit
InSphero Akura organ-on-chip family (Flow / Immune Flow / Twin): pre-formed spheroids and organoids with pumpless, tubeless gravity-driven flow for multi-organ, immune-cell and organ–organ interaction studies.
Product information
- Brand
- InSphero
- Catalog no.
- CS-KE11/CS-KD31
- Specification
- Akura organ-on-chip bundle (1 set)
Akura organ-on-chip technology
The Akura organ-on-chip system is a family of next-generation in vitro assay plates – Akura Twin, Akura Flow and Akura Immune Flow. It creates microphysiological systems (MPS) through microfluidic culture conditions, organ-to-organ interaction and the addition of immune cells under continuous flow: one technology that extends 3D cell culture into immune-competent microfluidic multi-organ experiments and makes them scalable.
Why choose Akura organ-on-chip technology?
1. Modular design built on pre-formed organoids and microtissues for higher biological consistency
The defining feature of Akura is not just the chip: standardised, high-quality 3D spheroids and organoids are built first and then connected to the microfluidic system – an advantage many conventional OoC systems lack. Benefits include:
- culture conditions can be optimised separately for each organ model;
- different tissue maturation times can be coordinated;
- quality control (QC) is done before the models go on the chip;
- single-organ function can be verified before a multi-organ system is built;
- overall system variability is greatly reduced.
Compared with approaches that culture cells directly in the chip, Akura usually gives better experimental stability, reproducibility and batch-to-batch consistency, closer to what pharmaceutical companies require of industrial data – an important reason why InSphero is easier to adopt in drug development than many academic-style OoC companies.
2. Physiological complexity with simple operation
A major pain point of the organ-on-chip field is that the more complex the physiological model, the harder the system is to run. Many systems rely on external pumps, tubing, bubble traps, engineering expertise and custom handling, which raises the learning curve, complicates maintenance, increases failure rates and makes routine use in pharma workflows hard to scale. The core idea of Akura is "complex biology without complex operation": continuous microfluidic culture that is pumpless, tubeless, gravity-driven and based on tilting perfusion. In practice this means easier start-up, stable chip operation, fewer bubble problems, more reliable long-term culture, less human error and a better fit for biology labs rather than engineering labs.
3. Standardisation and automation compatibility with real potential to scale
Many organ-on-chip products remain low-throughput, manual, academic research tools. Akura is designed from the start for standardisation and automation: it follows the ANSI/SLAS plate format and supports automated pipetting workstations, robotic liquid handlers, high-content imaging systems, plate readers and standard incubators. In particular, Akura Flow 384 provides 24 independent units with 12 compartments each, running many experimental conditions in parallel – something many OoC systems cannot do. Akura is therefore suited not only to mechanism studies but also to drug screening, drug–drug interactions (DDI), ADME, long-term toxicology, multi-organ metabolism studies and industrial preclinical workflows.
4. Built for complex multi-organ and immune studies, compatible with many downstream analyses
Akura supports multi-organ interaction (such as liver–gut and liver–lung), tumour–immune studies, immune-cell circulation, and inflammation and metastasis models. Akura Immune Flow addresses the settling and clogging of immune cells seen in conventional microfluidic systems and is better suited to immune-related research. The system is compatible with many downstream analyses, including RNA-seq/qPCR, omics, high-content imaging, live-cell observation, histology and real-time supernatant sampling, giving more analytical flexibility than some closed chip systems.
InSphero combines highly consistent 3D organoid models with an easy-to-use, scalable microfluidic system that suits standardised, large-scale use in drug development.
How to choose between the three Akura organ chips
| Item | Akura Flow | Akura Immune Flow | Akura Twin |
|---|---|---|---|
| Core positioning | Dynamic multi-organ culture | Suspension/immune cells + multiple 3D tissues | Interaction between two adjacent 3D tissues |
| 3D models | Spheroids / organoids / microtissues | Spheroids / organoids / microtissues | Spheroids / organoids / microtissues |
| Recommended model diameter | 150–600 µm | 200–600 µm | 200–800 µm |
| Suspension cells | Not recommended | Core function | Supported |
| Immune studies | Limited | Core application | One of the core applications |
| Organ interaction | Multi-organ | Multi-organ + suspension cells | Direct interaction of two adjacent tissues |
| Flow | Gravity-driven | Gravity-driven | Gravity-driven |
| Tilter | Recommended | Recommended | Recommended, used to generate flow |
| Typical tilt angle | ≤20° | Up to about 85° | 20–40° |
| Chip/plate material | Polystyrene | COC bottom | Polystyrene + COP bottom film |
| Main advantage | Flexible combination of several organ models | Circulating cells truly take part in the organ-on-chip experiment | Standardised, higher-throughput study of organ–organ interaction |
Frequently asked questions
Akura Flow
1. Which 3D models are suitable? Can suspension cells be added?
Scaffold-free organoids, spheroids and microtissues, ideally compact models about 150–600 µm in diameter formed in Akura 96 or Akura 384 spheroid microplates. Suspension cells are not recommended: they can settle within hours, accumulate in the reservoirs or block the microchannels. To study interactions of immune cells, metastatic tumour cells or engineered T cells with tissue, choose Akura Immune Flow.
2. What are the chip material and format?
Polystyrene with a 125 µm bottom and about 90% transmission at 400–800 nm, suitable for high-content imaging; its cell-repellent properties help maintain spheroid/organoid morphology and function. It follows the ANSI/SLAS microplate standard: 4 chips fit an aluminium handling frame with 4.5 mm compartment spacing (matching 384-well positions), giving 8 units of 10 culture compartments each, which hold spheroids up to about 600 µm in diameter.
3. How is flow generated? Is the Tilter required?
By gravity-driven perfusion: the frame with chips sits on the Akura Programmable All-In-One Tilter in the incubator and tilts back and forth, the chips moving about their short axis with a maximum tilt of about 20°, with no pumps or tubing. InSphero recommends this Tilter, whose programmable tilt angle, pause time and motion interval adjust flow rate and shear stress.
4. Can spheroids be formed in the chip? How are models loaded, and what analyses are possible?
The chip is designed for pre-formed models: form the spheroids and complete QC in Akura 96/384, then transfer them – which also makes it easy to combine multi-organ models with different culture times and media. Transfer can be manual, semi-automated or fully automated; for shear-sensitive models use low shear and sufficiently wide tips. Fluorescence and confocal live-cell imaging are supported, and after culture RNA sequencing, proteomics, mass spectrometry and other downstream analyses can be run.
Akura Immune Flow
5. How does it differ from Akura Flow?
A special microfluidic channel design reduces settling of suspension cells so they keep circulating and interact with several spheroids/organoids. Recommended model diameter is about 200–600 µm. Suspension cells used successfully include metastatic cancer cells, stimulated and unstimulated PBMCs and engineered T cells; in principle any cell that survives as a single-cell suspension can be considered, with the cell concentration optimised.
6. Flow and format?
It also follows ANSI SLAS 1-2004 (R2012): 4 chips in an aluminium frame with 4.5 mm compartment spacing, giving 8 units of 7 culture compartments each, which hold spheroids up to about 600 µm. Flow is gravity-driven, with the chips tilting about their short axis by up to about 85°; the near-vertical tilt keeps suspension cells moving and reduces settling and clogging. No pumps or tubing are needed, and use with the programmable Tilter is strongly recommended.
7. How long can it run, and which immune experiments are possible?
From hours to weeks, depending on the cell models and conditions; monitor viability and function during culture. Dynamic flow promotes interaction of suspended immune cells with the 3D models, so immune-cell infiltration, cytokine release and immunomodulation can be studied; afterwards the spheroids/organoids can be recovered for RNA sequencing, proteomics, mass spectrometry and more. When transferring fragile models use low-shear pipetting; 10–20 µL tips may be trimmed.
Akura Twin
8. What does Akura Twin address?
Organ–organ interaction between two adjacent 3D tissues, with immune cells able to take part: two culture compartments are connected by a microfluidic channel so soluble factors and single cells can move between the tissues while the spheroids/organoids stay in their own compartments. Recommended model diameter is about 200–800 µm; stimulated and unstimulated PBMCs have been used.
9. What are the compartment and channel dimensions?
| Part | Dimension |
|---|---|
| Spheroid culture compartment | 1 mm diameter × 600 µm high |
| Connecting channel | 1.6 mm wide × 100 µm high |
| Well spacing | 4.5 mm centre-to-centre (as in 384-well plates) |
10. How is flow generated? Can it run without the Tilter?
The microplate tilts back and forth on the Tilter, creating bidirectional gravity flow between the two compartments at a typical angle of 20–40°, with no pumps or tubing. The Tilter is required for fluid and cell exchange between compartments: at least 20° gives effective exchange of soluble factors, and migration of immune cells such as PBMCs between compartments needs tilts of up to about 40°.
11. Why do some channels at the edge run in a different direction?
These channels are parallel to the rotation axis and are not affected by effective tilting, so they can serve as no-flow controls for comparison with normal flow conditions.
12. What is the plate made of? Can spheroids be formed in the plate?
The plate body is polystyrene and the bottom film is 188 µm COP with about 92% transmission at 400–800 nm, suitable for high-resolution imaging. Akura Twin is for pre-formed models: complete aggregation and QC in Akura 96/384 first, then transfer to Akura Twin.