Products

Beonchip Microfluidic Chips

Beonchip microfluidic chips made of COP/COC – low gas permeability, low non-specific absorption and excellent optics – in four standard types (Be-Flow, Be-Transflow, Be-Doubleflow, Be-Gradient Barrier Free) plus custom chips for organ-on-chip and 3D culture research.

Product information

Brand
Beonchip
Catalog no.
Standard/custom
Specification
Set

Seven features of Beonchip microfluidic chips

  • Materials: cyclic olefin polymer (COP) and cyclic olefin copolymer (COC) are the preferred materials for all products. These medical-grade plastics are well suited to organ-on-chip and life-science applications.
  • Low permeability: the materials have very low oxygen and water-vapour permeability, so the gases inside the microchannels can be controlled precisely through their concentration and flow in the medium. With careful control of these parameters, hypoxia experiments can be run inside the chips.
  • No non-specific absorption problem: other materials commonly used for organ-on-chip (OoC) devices, such as PDMS, show non-specific absorption that rules them out for drug-testing experiments. COP and COC are lipophobic and do not have this problem, so they can be used for drug development and diffusion experiments.
  • Optical properties: COP and COC are transparent in the visible and near-UV range, with low birefringence and a high Abbe number, which makes them ideal for microscopy.
  • Chemical and heat resistance: COP and COC resist acids and polar solvents very well and have high glass-transition temperatures, close to 190 °C in some formulations.
  • Mass production: Beonchip products are made by thermoplastic injection moulding, which keeps batches reproducible and allows high-volume production without loss of quality.
  • Microfluidic compatibility: the fluidic connections are designed for syringe pumps, peristaltic pumps and pressure-based flow controllers; adapters compatible with Luer or barbed connections of your flow-control system are available.

Beonchip chip types

Beonchip offers standard chips and custom chips. The four standard types are:

Be-Flow

Be-Flow is designed for cell culture under medium flow. It allows long-term 2D or 3D culture in two independent channels. Be-Flow is compatible with a wide range of microfluidic pump systems and, thanks to the fluid reservoirs at its inlets and outlets, can also simply be used on a rocker.

Applications: vascular research and processes related to cell adhesion to the vascular endothelium (infection, cell therapy, metastasis and more).

  • Ayuso, J. M. et al. SU-8 Based Microdevices to Study Self-Induced Chemotaxis in 3D Microenvironments. Front. Mater. 2, 1–10 (2015). This study examined SU-8 as a structural material for complex cell-culture microdevices and showed, in the SU-8-based Be-Flow device, cells migrating towards a nutrient source when nutrient limitation was combined with their natural metabolism.

Be-Transflow

Be-Transflow connects a culture well to a microfluidic channel through a porous membrane, enabling complex culture configurations. It is well suited to air–liquid interface (ALI) culture, endothelial/epithelial barriers and interaction studies.

Applications: in vitro immune-system models, atherosclerotic plaque formation, epithelial adhesion and more.

  • Olaizola-Rodrigo et al. Reducing Inert Materials for Optimal Cell–Cell and Cell–Matrix Interactions within Microphysiological Systems. Biomimetics, 9, 262 (2024).
  • Fernandez-Carro, E. et al. Human Dermal Decellularized ECM Hydrogels as Scaffolds for 3D In Vitro Skin Aging Models. Int. J. Mol. Sci., 25, 4020 (2024).

Be-Doubleflow

Be-Doubleflow consists of two perfusable channels connected through a porous membrane. It is used to explore interactions between different 2D and 3D cultures in a biomimetic environment, with the pore size chosen to control how efficiently the two sides interact.

Applications: studies that need gas control (hypoxia, anoxia, ischaemia–reperfusion), studies of circulating particles (bacteria, immune cells, circulating tumour cells) and endothelial/epithelial barriers, particularly where flow matters on both sides of the co-culture.

  • Stankovic, T. et al. In vitro biomimetic models for glioblastoma – a promising tool for drug response studies. Drug Resistance Updates. 55, 100753 (2021).

Be-Gradient Barrier Free

Be-Gradient Barrier Free is designed to apply chemical gradients in 3D cell culture. It consists of one cell-culture chamber in direct contact with two channels; changing the concentration of a component between the two side channels creates a chemical gradient. It is compatible with inverted phase-contrast, confocal and fluorescence microscopes.

Applications: cell or spheroid invasion and migration, angiogenesis, metastasis, chemotaxis, ischaemia, cell differentiation and oxidative stress.

  • Bayona, C. et al. Development of an organ-on-chip model for the detection of volatile organic compounds as potential biomarkers of tumour progression. Biofabrication 16, 045002 (2024).
  • Olaizola-Rodrigo et al. Tuneable hydrogel patterns in pillarless microfluidic devices. Lab Chip 24, 2094–2106 (2024).

Custom chips

Chips can be customised for your research by microchannel dimensions, base thickness, pore size, base type and other parameters.

Selected publications

  • Fernandez-Carro, E. et al. Human Dermal Decellularized ECM Hydrogels as Scaffolds for 3D In Vitro Skin Aging Models. Int. J. Mol. Sci., 25, 4020 (2024).
  • Fernandez-Carro, E. et al. Nanoparticles Stokes radius assessment through permeability coefficient determination within a new stratified epithelium on-chip model. Artificial Cells, Nanomedicine, and Biotechnology, 51(1), 466–475 (2023).
  • González-Lana, S. Surface modifications of COP-based microfluidic devices for improved immobilisation of hydrogel proteins: long-term 3D culture with contractile cell types and ischaemia model. Lab on a Chip (2023).
  • Ayensa-Jiménez, J. et al. Analysis of the parametric correlation in mathematical modeling of in vitro glioblastoma evolution using copulas. Mathematics, 9(1), 27 (2021).
  • Pérez-Aliacar, M. et al. Predicting cell behaviour parameters from glioblastoma on a chip images. A deep learning approach. Computers in Biology and Medicine, 135, 104547 (2021).
  • Ayensa-Jiménez, J. et al. Mathematical formulation and parametric analysis of in vitro cell models in microfluidic devices: application to different stages of glioblastoma evolution. Scientific Reports, 10(1), 21193 (2020).
  • Virumbrales-Muñoz, M. et al. Enabling cell recovery from 3D cell culture microfluidic devices for tumour microenvironment biomarker profiling. Sci. Rep. (2019).
  • Ayuso, J. M. et al. Glioblastoma on a microfluidic chip: Generating pseudopalisades and enhancing aggressiveness through blood vessel obstruction events. Neuro. Oncol. 19, now230 (2017).
  • De Miguel, D. et al. TRAIL-coated lipid-nanoparticles overcome resistance to soluble recombinant TRAIL in non-small cell lung cancer cells. Nanotechnology 27, 185101 (2016).
  • De Miguel, D. et al. Improved Anti-Tumor Activity of Novel Highly Bioactive Liposome-Bound TRAIL in Breast Cancer Cells. Recent Pat. Anticancer Drug Discov. 11, 197–214 (2016).
  • De Miguel, D. et al. High-order TRAIL oligomer formation in TRAIL-coated lipid nanoparticles enhances DR5 cross-linking and increases antitumour effect against colon cancer. Cancer Lett. 383, 250–260 (2016).
  • Ayuso, J. M. et al. Development and characterization of a microfluidic model of the tumour microenvironment. Sci. Rep. 6, 36086 (2016).
  • Martínez-González, A. et al. Systems Biology of Tumor Microenvironment. Vol. 936 (Springer International Publishing, 2016).

Frequently asked questions

Product and materials

1. Are the chips sterile on arrival?

Yes. All chips are sterilised after manufacture and individually packed; the manufacturer states that they stay sterile and hydrophilic for 6 months after shipment.

2. Do the chips autofluoresce?

The chips are made mainly of COP (cyclic olefin polymer), which has low autofluorescence and suits fluorescence experiments and imaging with standard imaging equipment. Be-Gradient Barrier-Free has a special surface treatment and may show slight autofluorescence, but it can still be used for fluorescence experiments and imaging.

3. Is there non-specific absorption?

COP is an inert, lipophobic material. Compared with silicone-based materials such as PDMS it is much less prone to marked non-specific absorption, which reduces interactions between the material, the medium and the test compounds. This makes it particularly suitable for efficacy and toxicity studies.

4. Why COP/COC as the chip material?

COP and COC have low gas and water-vapour permeability, low non-specific absorption and good optical properties, which suits life-science and organ-on-chip applications. Low gas permeability also lets researchers control the gas environment inside the microchannels more precisely.

5. COP is not oxygen-permeable – how do the cells get oxygen?

Cells take up oxygen from the medium. In organ-on-chip experiments the low oxygen permeability of COP is an advantage: by controlling the oxygen concentration and flow of the medium, the oxygen environment in the chip can be controlled more accurately, so hypoxic conditions can also be established and studied.

Connections and flow control

6. Which connectors do I need?

Beonchip offers several connector kits, chosen by flow-control method and tubing type; the main ones currently are semi-rigid tubing + peristaltic pump, semi-rigid tubing + syringe pump, soft tubing + peristaltic pump, and soft tubing + syringe pump.

7. If I use a rocker to generate shear, do I still need connectors?

No. The chips can be used directly, but with the chip lid in place to reduce the risk of contamination. The manufacturer also recommends using a rocker in the early phase of culture and connecting the final microfluidic control system once the cells are stable.

8. Can several chips be connected in series?

Yes. With the appropriate connectors several chips can be connected in series, which is particularly useful for studying interactions and crosstalk between tissues, for example in multi-organ systems.

9. Must I use a HEPES-containing medium?

Not necessarily. When the chip sits in a CO₂ incubator without continuous perfusion, the incubator atmosphere maintains the pH. For continuous perfusion the manufacturer strongly recommends HEPES: the medium is usually held in reservoirs, tubing and other parts, where its gas exchange with the incubator CO₂ atmosphere may be limited, causing pH fluctuations. As an additional buffer, HEPES helps improve cell viability and attachment, reproducibility and long-term perfusion stability.

Chemical compatibility

10. Can I use isopropanol (IPA)?

Yes. The chips are made of COP/COC, PET and similar materials, and isopropanol is generally safe for cleaning or sterilisation; ethanol is also well tolerated under normal laboratory conditions.

11. Can I use acetone?

Not recommended. Acetone can swell COP/COC, degrade surface properties, change optical properties, damage structural integrity and affect the bonded interfaces of the chip. Use isopropanol or ethanol for cleaning or sterilisation; if contact with another solvent is unavoidable, test material compatibility first.

Cell recovery and downstream analysis

12. Can cells be recovered after the experiment?

Yes, by dissociation: remove the medium → wash with PBS → add a suitable dissociation solution → incubate as appropriate for the cell type → add stop solution → tilt the chip if needed to help mixing → pipette gently at the inlet/outlet ports to detach the cells → check under the microscope → collect all liquid from the chip to obtain the cells. The manufacturer has a detailed technical document on cell extraction, available from TechWave on request.

13. Can the recovered cells be used for molecular analysis?

Yes – gene-expression, protein and other downstream analyses can be run according to the aim of the experiment.

Customisation and reuse

14. Can standard chips be customised?

Structural parameters such as membrane pore size and microchannel dimensions and shape can be customised; for example, the membrane pore size of Be-Transflow and Be-Doubleflow can be adjusted to your needs.

15. Can you integrate our own membrane?

Yes. This is a Beonchip custom service; the cost depends on how difficult the membrane is to handle and how complex it is to integrate into the chip manufacturing process, and it is quoted as a custom product.

16. Can you develop a completely new chip?

Yes. Besides modifying the parameters of existing products, Beonchip can take a customer's organ-on-chip, microfluidic or biomedical design concept from prototype through to volume production.

17. Can the chips be reused?

No. Cells, ECM coatings and medium leave residues in the microchannels, and even after cleaning and dissociation the chip cannot be guaranteed to match the cleanliness and conditions of a new one. To keep results consistent and reproducible, the manufacturer recommends a new chip for every experiment.

18. Can connectors and tubing be reused?

Most fluidic connectors and tubing can be reused after proper sterilisation: wash with water and soap, then autoclave (example conditions 121 °C for 15–20 minutes); sterilise before use and between experiments. Some accessories, such as chip lids and Be-Transflow Well Seals, should not be autoclaved.